Test signals choice for system characteristics identification: Taking into account the output deviation range constraint

Test signals choice for system characteristics identification: Taking into account the output deviation range constraint

0.00 Avg rating0 Votes
Article ID: iaor20163583
Volume: 77
Issue: 9
Start Page Number: 1656
End Page Number: 1664
Publication Date: Sep 2016
Journal: Automation and Remote Control
Authors: , ,
Keywords: optimization
Abstract:

This paper considers active identification methods for the temporal characteristics of an object in a closed‐loop control system. A comparative analysis of binary signals, namely, pseudorandom and regular sequences of rectangular pulses, is performed under a constraint imposed on the output deviation range of the controlled parameter. Using calculations, it is shown that the best signal choice depends on several factors and, first of all, on the noise level; under a sufficiently small noise level, the regular binary sequence of rectangular pulses seems preferable.