Article ID: | iaor2016980 |
Volume: | 32 |
Issue: | 3 |
Start Page Number: | 1021 |
End Page Number: | 1028 |
Publication Date: | Apr 2016 |
Journal: | Quality and Reliability Engineering International |
Authors: | Hamada M S, Burkhardt J H |
Keywords: | control |
This article considers the impact of a measurement system that meets an L:1 rule on various quality activities. These activities include inspection, acceptance sampling, and control charting. A measurement system that meets a 10:1 rule performs much better than one that meets a 4:1 rule. R code is provided so that the practitioner can evaluate these activities to his or her particular situation.