Optimum thickness of curtain grouting on dam foundation with minimum seepage pressure resultant

Optimum thickness of curtain grouting on dam foundation with minimum seepage pressure resultant

0.00 Avg rating0 Votes
Article ID: iaor2012355
Volume: 45
Issue: 2
Start Page Number: 303
End Page Number: 308
Publication Date: Feb 2012
Journal: Structural and Multidisciplinary Optimization
Authors: ,
Keywords: construction & architecture, engineering, design
Abstract:

The distribution of hydraulic head on the dam foundation plane with curtain grouting is analyzed by the simplified one‐dimensional seepage model, also is studied the effect of various parameters of curtain grouting on seepage pressure on the foundation plane. The theory of the optimum thickness of curtain grouting is proposed from the viewpoint of the minimum seepage pressure resultant and proved by the two‐dimensional seepage model and the finite element method, which includes two cases of homogenous foundation and layered foundation.