| Article ID: | iaor2001239 |
| Country: | Netherlands |
| Volume: | 32 |
| Issue: | 2 |
| Start Page Number: | 249 |
| End Page Number: | 266 |
| Publication Date: | Dec 2000 |
| Journal: | Engineering Optimization |
| Authors: | Hwang H., Lim J.M., Moon S.W., Chang I.H. |
| Keywords: | design, optimization |
The objective of this paper is the development of a design model for refrigerated automated storage and retrieval systems (R-AS/RS). Compared with ordinary unit-load AS/RS, the R-AS/RS under this study has several different design and operating characteristics: (1) greater emphasis is placed on the storage function and so it has a double-depth lane in the storage rack; (2) cooling units are required to maintain a cold temperature environment in the system; (3) the maximum number of storage orders handled per unit time is limited by the system capacity. Considering the above characteristics, the design problem is formulated as a non-linear mixed integer programming problem in which the cost of the system is minimized. The decision variables are the storage volume, the number of storage and retrieval (S/R) machines, the type and number of cooling units, and the physical configuration of the building. A case problem is solved to illustrate the model.