Reliability analysis of a two-unit cold standby redundant system subject to a priority rule

Reliability analysis of a two-unit cold standby redundant system subject to a priority rule

0.00 Avg rating0 Votes
Article ID: iaor1990123
Country: Belgium
Volume: 31
Start Page Number: 159
End Page Number: 166
Publication Date: Mar 1989
Journal: Cahiers du Centre d'tudes de Recherche Oprationnelle
Authors:
Keywords: cold standby
Abstract:

The paper studies a two-unit cold standby redundant system subject to a priority rule and a preventive maintenance policy. All p.d.f’s involved are general. An important realistic behaviour of this model is characterized by the assumption that the non-priority unit has a memory i.e., it remembers the total elapsed operative time upon switch from standby to the operative state and conversely. The latter characteristic does not seem to be invoked in previous reliability models. A numerical example, with a computer-plotted graph for the mean life time of the system as a function of the replacement time, shows the optimal scheduled age replacement.